INSTALLER INSTRUCTIONS
CONTENTS
1 DESCRIPTION OF THE BOILER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pag. 102
2 INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pag. 104
3 CHARACTERISTICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pag. 111
4 USE AND MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pag. 114
IMPORTANT
When carrying out commissioning of the boiler, you are highly recommended to perform the following checks:
Make sure that there are no liquids or inflammable materials in the immediate vicinity of the boiler.
Make sure that the electrical connections have been made correctly and that the earth wire is connected to a
good earthing system.
Open the gas tap and check the soundness of the connections, including that of the burner.
Make sure that the boiler is set for operation for the type of gas supplied.
Check that the flue pipe for the outlet of the products of the combustion is unobstructed and has been pro-
perly installed.
Make sure that any shutoff valves are open.
Make sure that the system is charged with water and is thoroughly vented.
Check that the circulating pump is not locked.
Purge the system, bleeding off the air present in the gas pipe by operating the pressure relief valve on the gas
valve inlet.
FONDERIE SIME S.p.A. of Via Garbo 27 - Legnago (VR) - Italy declares that its hot water boilers, which bear the
CE mark under Gas Directive 90/396/CEE and are fitted with a safety thermostat calibrated to a maximum of
11C, are not subject to application of PED Directive 97/23/CEE as they meet the requirements of article 1
paragraph 3.6 of the Directive.
PLANET DEWY 60 BFR - ENGLISH
Vue de la page 0
1 2 3 4 5 6 ... 29 30

Résumé du contenu

Page 1 - INSTALLER INSTRUCTIONS

INSTALLER INSTRUCTIONSCONTENTS1 DESCRIPTION OF THE BOILER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Page 2

110ITESFRBEGB2.8.3 Gradient of the characteristicheating curveThe gradient of the characteristic heatingcurve is imposed on the current value “15

Page 3 - 23-53 / C13-33-43-53-83

3.1 ELECTRONIC BOARDBuilt according to Low Voltage direc-tive CEE 73/23 and powered at 230Volt, via a transformer it sends 24Volt power to the followi

Page 4 - S3 Condensation outlet

112ITESFRBEGB3.2 TEMPERATURE PROBE AND WATER PRESSURETRANSDUCERAntifreeze system made up of the NTCheating sensor that activates whenthe water tempera

Page 5 - Load loss

off the burner, when power is restored,the boiler will automatically start.3.4 AIR PRESSURE SWITCHThe pressure switch signal value ismeasured by a spe

Page 6

114ITESFRBEGB4.1 GAS VALVEThe boiler, is equipped standard withthe SIT 848 SIGMA gas valve (fig. 16).4.2 ADJUSTMENTHEATING POWERTo adjust heatin

Page 7 - EXTERNAL SENSOR

115ITESFRBEGB“∆p air” ADJUSTMENTTo measure “∆p air” simply con-nect the differential pressuregauge, equipped with a decimalscale in mm or

Page 8

116ITESFRBEGB4.4 SHELL REMOVALFor easy boiler maintenance the shellcan be completely removed by fol-lowing these instructions (fig. 19):- Pull th

Page 9

117ITESFRBEGBBOILER IGNITION (fig. 1)Open the gas tap, lower the controlcover and turn on the boiler by rota-ting the selector knob to winter ( ).

Page 10

118ITESFRBEGBone for which the boiler has beenequipped, approach the technicalstaff.CLEANING AND MAINTENANCEPreventive maintenance andchecking of th

Page 11 - 2O for propane gas

119ITESFRBEGBWhen the boiler is connected to the “Logi-ca Remote Control” regulator, the selectorCR/OFF/SUM/WIN/UNBLOCK must beplaced in the positio

Page 12

102ITESFRBEGB1.1 INTRODUCTION“PLANET DEWY 60 BFR” boilers (suppliedas Class B devices) are pre-mixed conden-sation heating modules intended only fo

Page 13 - Connettore J2

120ITESFRBEGBIf it is too hot or too cold in your apartment, you can easily adjust the fixedtemperature with the temperature knob.Before adjusting it

Page 14 - 2O mm H2O kg/h

121ITESFRBEGBIf the rooms remain unused for a long period of time, the temperatu-re can be reduced with the on-line key, in this way saving energy. Wh

Page 15 - Pressostato

122ITESFRBEGB– Programme for hot-water service (with storage capacity boiler unit)Select the days that correspond with the heating phase. 1= Monday, .

Page 16 - FLASHING YELLOW LED

123ITESFRBEGB– Default valuesTo take the setting to the default values, press the and keys at thesame time for at least 3 seconds. As confirmat

Page 17 - USER INSTRUCTIONS

124ITESFRBEGBDomestic hot water sensor fault (with storage capacity boiler unit)Call an authorised Service Centre.67686970192193195Heating sensor faul

Page 18

DICHIARAZIONE DI CONFORMITA’ CALDAIE MURALI A GASLa FONDERIE SIME S.p.A., con riferimento all’art. 5 DPR n°447 del 6/12/1991 “Regolamento diattuazio

Page 19

Rendimenti caldaie murali a gas DPR 412/93 e DPR 551/99MODELLO Potenza termica Portata termica Rendimento a carico nominale Rendimento al 30% del cari

Page 20

CERTIFICATO DI ORIGINE E CONFORMITÀDEI DISPOSITIVI AUTOMATICI DI SICUREZZA E DEL BRUCIATORE A NORME DELLE CIRCOLARI N° 68 DEL 25.11.1969 E N° 42 DEL 2

Page 23

103ITESFRBEGB1.4 TECHNICAL FEATURESPLANET DEWY 60 BFRHeat output nominal (80-60°C) kW (kcal/h) 56,6 (48.600)Heat output nominal (50-30°C) kW (kcal/h)

Page 24

Fonderie Sime S.p.A - Via Garbo, 27 - 37045 Legnago (Vr) Tel. + 39 0442 631111 - F a x +39 0442 631292 - www.sime.itCod. 6274234A - Doc

Page 25

104ITESFRBEGBThe boiler must be installed in a fixed loca-tion and only by specialized and qualifiedfirms in compliance with all instructionscontained

Page 26

105ITESFRBEGBFor long-term protection agains corrosionand deposits, the use of inhibitors such asSentinel X100 is recommended after clea-ning the

Page 27

106ITESFRBEGBbe 230V - 50Hz single-phase through afused main switch, with at least 3 mm spa-cing between contacts. Respect the L and N pola

Page 28

107ITESFRBEGB2.7.4 Wiring diagramJ2J3J4J5J7Fig. 9KEYEV1 Gas valve coilEV2 Gas valve coilEA Ignition electrodeER Detection electrodeTS Safety therm

Page 29

108ITESFRBEGB2.8 LOGICA REMOTE CONTROLAll the boiler's functions can be managedby a optional digital multifunctional devicecode 8092204 for the r

Page 30

109ITESFRBEGBDOMESTIC HOT WATER SETTINGSReduced domestic hot water pre-set valueDomestic hot water loadThe reduced pre-set value of the temperature of